High-voltage revenue metering depends on keeping the metering circuit independently controlled, not just on switching functions. In the KYN28-12 and KYN61-40.5 metering cabinets, the metering compartment is separate from the breaker and busbar compartments.
Send Inquiry

High Voltage Gas Insulated Switchgear

Sealed Metering Compartments for Utility-Side Billing

 

High-voltage revenue metering depends on keeping the metering circuit independently controlled, not just on switching functions. In the KYN28-12 and KYN61-40.5 metering cabinets, the metering compartment is separate from the breaker and busbar compartments. Current transformers and the energy meter can be sealed independently, making the arrangement suitable for utility metering points where the supply authority requires seals. The compartment can be sealed and isolated, and the cabinet maintains the required insulation clearances for its voltage class, with IP4X as the standard protection degree.

0.2S Accuracy During Light-Load Periods

 

Current transformers are available in 0.2S or 0.2 accuracy classes. The 0.2S option maintains accuracy at low currents, covering both normal loads and light-load periods to simplify acceptance under local metering rules. Metering uses a combined current transformer and voltage transformer arrangement for high-voltage measurement on the high-voltage side. Space is reserved inside for secondary CT terminals, the VT secondary circuit and meter mounting. Meter positions and wiring follow the local supply authority's metering requirements. This High Voltage Gas Insulated Switchgear can be installed alongside incoming, outgoing and other cabinets from the same series.

Where the Metering Unit Fits

 

Typical applications include 6kV, 10kV and 35kV user distribution rooms with high-voltage metering on an incoming or branch circuit; industrial parks, commercial buildings and factory high-voltage rooms; and utility metering points where the supply department requires sealed management and independent isolation of the metering transformers.

Purchase and Delivery Notes

 

Meter positions and wiring can be arranged to meet local grid metering requirements, reducing rework on site. Standard units take about 30 working days, while customized units take about 60 working days. Each unit undergoes 100% inspection before packing. Export shipments use wooden cases, and the warranty period is one year from delivery. The High Voltage Gas Insulated Switchgear is supplied according to the confirmed project configuration.

Product Specifications

Parameter

Specification

Rated voltage

6kV, 10kV (KYN28-12); 35kV (KYN61-40.5)

Metering mode

Combined CT + VT metering; high-voltage metering supported

CT accuracy

0.2S class or 0.2 class (standard metering configuration)

Structure

Armored metal-clad metering cabinet with a sealable metering compartment

Protection degree

IP4X (standard)

Hot Tags: high voltage gas insulated switchgear, China high voltage gas insulated switchgear manufacturers, suppliers, factory, High Voltage Electrical Switchgear, High Voltage Gear, high voltage switchgear, HV and LV Switchgear, HV Switch Gear, MV HV Switchgear